Brugsanvisning GEV FMR 3033 FlammEx Røgalarm

Har du brug for en brugsanvisning til din GEV FMR 3033 FlammEx Røgalarm? Nedenfor kan du se og downloade PDF-brugsanvisningen gratis på Dansk. Dette produkt har i øjeblikket 3 ofte stillede spørgsmål, 1 kommentar og har 2 stemmer med en gennemsnitlig produktvurdering på 0/100. Hvis dette ikke er den brugsanvisning, du ønsker, bedes du kontakte os.

Er dit produkt defekt, uden at brugsanvisningen har en løsning på problemet? Tag til en Repair Café, og få gratis reparation.

Brugsanvisning

Loading…

7 6
Operation of a smoke detector is limited in the following
areas:
• in bathrooms, garages or kitchens.
• in drafty areas, e.g. near ventilator shafts.
• in extremely dusty areas.
• in areas with high ambient humidity.
Minimum protection
Maximum protection
Mounting and installation
• Choose a suitable area to mount the detector, on the
ceiling in the centre of the room according to Fig. 5 to
Fig. 7.
• Follow the installation instructions according to Fig. 7.
No objects or obstacles should be found within a
50 cm radius around the smoke detector.
• Attach the mounting plate to the ceiling according to
Fig. 3.
• Insert the battery and connect it correctly according
to Fig. 2. The red LED fl ashes approx. every 45
seconds Fig. 3C.
• Place the smoke detector onto the installed mounting
plate and carefully turn it in a clockwise direction until it
clicks into place Fig. 3A + 3B.
• Check that each installed smoke detector is operating
correctly using the test key Fig. 3C.
Comprehensive alarm system and connecting
several smoke detectors together
To immediately and clearly hear the warning signal of
each individual smoke detector, we recommend that you
connect the individual smoke detectors together.
Up to 30 smoke detectors can be connected together by
wire or radio.
• Use J-Y(St)Y2x2x0.6 or AWG 23 wires and connect
them according to Fig. 4. Make sure the cables are
connected correctly: plus to plus and minus to minus.
• Connect individual smoke detectors according to Fig. 4.
• When all smoke detectors have been connected
together, perform a function test.
• Press and hold the test key Fig. 3C on a connected
smoke detector for approx. 20 seconds to trigger the
alarm on all the smoke detectors.
Function
The smoke detector automatically performs a self-test
every 45 seconds. The LED fl ashes briefl y to indicate this.
• Test the device each time you replace the battery.
• Check that the smoke detector is operating correctly at
least once a year using the test key Fig. 3C.
Battery and rechargeable battery information
Old batteries may not be disposed of with the
unsorted household waste. Owners of used
batteries are legally obliged to recycle the batteries
and can return them free of charge to the place of
sale. Batteries contain material which is harmful to the
environment and health, and must therefore be disposed
of professionally.
Recycling instructions
This device must not be disposed of with unsorted
household waste. Owners of old devices are
required by law to dispose of this device correctly.
Contact your town council for further information.
Correct action in the event of a fi re
Keep calm!
Alert the fi re service.
It is important that the fi re service is told the following
information:
• Your name (name, phone number)
• The location of the fi re (address)
• What has happened (extent of fi re)
• How many people are injured
• Then wait to see if the operator has any questions.
Alert all the people who live with you.
Help aged, sick and disabled persons.
Close all windows and doors.
Do not use lifts.
If you have any doubts as to whether or not it is a genuine
alarm, still act as if there is a real fi re.
Tone Red LED Description
Intermittent alarm signal Flashes at the same time as the
audible alarm signal
Alarm triggered on individual detector if
smoke is detected. Automatically resets
if no smoke is detected
Intermittent alarm signal No LED Alarm triggered by connected detector.
The triggered detector can be identifi ed
by an intermittent alarm signal and
ashing LED. Automatically resets if no
smoke is detected
Short signal emitted approx.
every 45 seconds
Flashes at the same time as the
audible signal
Replace the battery
No signal Flashes every 45 seconds Device is ready for use
Short signal emitted approx.
every 45 seconds
Flashes alternately with the
audible signal
Faulty, replace the device
Technical information
Product Smoke alarm FMR 3033, FMR 3392, type 32
Smoke alarm FMR 3569, type 34
Alarm display visual (red LED) and acoustic
Operating voltage FMR 3033, FMR 3392, 9 V
,
alkaline battery included
FMR 3569, 9 V
, lithium battery included
Recommended batteries Ultralife U9VL lithium battery, Energizer 6LR61, Duracell MN1604, Power Line 6LR61
Temperature range 0 °C...+55 °C
Signal volume 85 dB/3 m
CPD number 0786-CPD-20564
VdS number G200057
Standard DIN EN 14604:2009-02
CE marking 2011
Measurements Ø 110 mm x H 40 mm
Gutkes GmbH
Rehkamp 13
30853 Langenhagen
Germany
Fax: +49 (0)511/95 85 805
www.gev.de
service@gev.de
Technical and design features may be subject to change.
Table of functions
DGBFNLIESDKFINRUSGRESTLVLTPLPROSLOSKCZTR NH
Download brugsanvisningen på Dansk (PDF, 0.4 MB)
(Tag hensyn til miljøet, og udskriv kun denne brugsanvisning, hvis det er virkelig nødvendigt)

Loading…

Bedømmelse

Fortæl os, hvad du synes om GEV FMR 3033 FlammEx Røgalarm ved at lave en produktbedømmelse. Vil du dele dine oplevelser med dette produkt eller stille et spørgsmål? Skriv en kommentar nederst på siden.
Er du tilfreds med GEV FMR 3033 FlammEx Røgalarm?
Ja Ingen
0%
100%
2 stemmer

Deltag i samtalen om dette produkt

Her kan du dele, hvad du synes om GEV FMR 3033 FlammEx Røgalarm. Hvis du har et spørgsmål, skal du først læse brugsanvisningen omhyggeligt. Anmodning om en brugsanvisning kan ske ved at bruge vores kontaktformular.

Daniela Rick 01-08-2019
Hvad gør jeg, hvis røgdetektoren lyder umiddelbart efter, at det nye batteri er sat i, inklusive alle røgdetektorer i vores hus.

svar | Dette var nyttigt (21) (Oversat af Google)

Mere om denne brugsanvisning

Vi forstår, at det er rart at have en papirbrugsanvisning til din GEV FMR 3033 FlammEx Røgalarm. Du kan altid downloade brugsanvisningen fra vores hjemmeside og selv printe den. Hvis du gerne vil have en original brugsanvisning, anbefaler vi, at du kontakter GEV. De kan muligvis levere en original brugsanvisning. Leder du efter brugsanvisningen til din GEV FMR 3033 FlammEx Røgalarm på et andet sprog? Vælg dit foretrukne sprog på vores hjemmeside, og søg efter modelnummeret for at se, om vi har det tilgængeligt.

Specifikationer

Mærke GEV
Model FMR 3033 FlammEx
Kategori Røgalarmer
Filtype PDF
Filstørrelse 0.4 MB

Alle brugsanvisninger til GEV Røgalarmer
Flere brugsanvisninger til Røgalarmer

Ofte stillede spørgsmål om GEV FMR 3033 FlammEx Røgalarm

Vores support-team søger efter nyttige produktoplysninger og svar på ofte stillede spørgsmål. Hvis du finder urigtigheder i vores ofte stillede spørgsmål, må du meget gerne lade os det vide ved at bruge vores kontaktformular.

Hvor bør jeg opstille min røgdetektor? Verificeret

Det afhænger af situationen, men i et hjem er det bedst at opstille mindst én røgdetektor på hver etage. Prøv at opstille dem i gange eller andre rum, der forbinder forskellige rum med hinanden, og opstil aldrig røgdetektoren direkte ved siden af et køkken eller badeværelse. Sørg også for, at der er mindst 30 cm afstand mellem en røgdetektor og en lampe.

Dette var nyttigt (306) Læs mere

Kan jeg bruge stearinlys, hvis jeg har en røgdetektor? Verificeret

Dette afhænger delvist af røgdetektorens følsomhed. I mange tilfælde kan et lys bruges, så længe det ikke placeres i nærheden af ​​røgdetektoren. Når lyset blæses ud, kan der dannes røg, der kan udløse røgdetektoren.

Dette var nyttigt (75) Læs mere

Er en røgdetektor det samme som en kulilte-detektor? Verificeret

Ingen! En røgdetektor fungerer ikke som kulilte detektor og omvendt.

Dette var nyttigt (44) Læs mere
Brugsanvisning GEV FMR 3033 FlammEx Røgalarm

Relaterede produkter

Relaterede kategorier

×
Download