Brugsanvisning ETNA 4265NZT Emhætte

Har du brug for en brugsanvisning til din ETNA 4265NZT Emhætte? Nedenfor kan du se og downloade PDF-brugsanvisningen gratis på Dansk. Dette produkt har i øjeblikket 2 ofte stillede spørgsmål, 0 kommentarer og har 0 stemmer. Hvis dette ikke er den brugsanvisning, du ønsker, bedes du kontakte os.

Er dit produkt defekt, uden at brugsanvisningen har en løsning på problemet? Tag til en Repair Café, og få gratis reparation.

Brugsanvisning

Loading…

3
ENGLISH
GENERAL
Carefully read the following important information regarding installa-
tion safety and maintenance. Keep this information booklet accessible
for further consultations.
The appliance has been designed as a exhausting version (external
exhaust) or as a filter version (internal air recycle) cooker hood.
SAFETY PRECAUTION
1. ake care when the cooker hood is operating simultaneously with an
open fireplace or burner that depend on the air in the environment and
are supplied by other than electrical energy, as the cooker hood re-
moves the air from the environment which a burner or fireplace need
for combustion.
The negative pressure in the environment must not exceed 4 Pa
(4 x 10 -5 bar).
Provide adequate ventilation in the environment for a safe operation of
the cooker hood.
Follow the local laws applicable for external air evacuation.
2. WARNING!!
In certain circumstances electrical appliances may be a danger
hazard.
A) Do not check the status of the filters while the cooker hood
is operating
B) Do not touch the light bulbs after appliance use
C) Flambè cooking is prohibited underneath the cooker hood
D) Avoid free flame, as it is damaging for the filters and a fire
hazard
E) Constantly check food frying to avoid that the overheated oil
may become a fire hazard
F) Disconnect the electrical plug prior to any maintenance.
INSTALLATION INSTRUCTIONS
• Electric Connection
The appliance has been manufactured as a class II, therefore no earth
cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indicated on the
description label. Where a plug is provided, the cooker hood must be
installed in order that the plug is easily accessible.
An omnipolar switch with a minimum aperture of 3mm between con-
tacts, in line with the electrical load and local standards, must be placed
between the appliance and the network in the case of direct connection
to the electrical network.
• The appliance must be installed at a minimum height of 650 mm from
an cooker stove.
If a connection tube composed of two parts is used, the upper part must
be placed outside the lower part.
Do not connect the cooker hood exhaust to the same conductor used
to circulate hot air or for evacuating fumes from other appliances gen-
erated by other than an electrical source.
ATTENTION: should the lamps not work, make sure they are well
tightened.
MOUNTING OF THE HOOD BETWEEN TWO HANGING CUP-
BOARDS
Drill 2 holes of 2,5 mm diameter on the side of the hanging cupboards
as showed in the fig. 1 considering also the thickness of the front panel,
so that the hood remains at the same level of the side hanging
cupboards.
Fix the hood to the hanging cupboards through 4 screws, which are
appropriate to that kind of cupboard. .
Close the room, which eventually remains between the hood and the
wall adjusting the spacer (L) by acting on the appropriate screws (P)
fig. 1.
MOUNTING OF THE HOOD ON THE WALL
Drill 6 holes on the wall as showed in fig. 2.
Fix the spacer (L) on the wall at the right height, according to the depth
of the hanging cupboards fig. 2.
Adjust the position of the superior clamps (M) fig. 2, according to the
depth of the side hanging cupboards.
Fix the hood on the wall through 4 screws and dowels with expanding
plug , which are appropriate to that kind of wall (ex. concrete, plaster-
board, etc.).
Fix the hood to the spacer through the screws (P) fig. 1.
FIXING OF THE FRONT PANEL
Take off the door (E) by removing the grill (G) and pulling at the same
time the special spring locking knobs (H) fig. 3.
Fix the door on the front panel through the screws at the level indicated
in fig. 3.
Replace the door by inserting it in the upper and lower slides until the
spring locking knobs (H) are released.
EXHAUSTING VERSION
Insert the coupling flange (B) in the hole (A) and connect the discharge
pipe to the same fig. 1.
FILTERING VERSION
Demand your dealer the active carbon filter, if they are not supplied.
Active carbon filters are necessary to depurate the air, that will be
released in the room. Filters are not washable; they cannot be regen-
erated and have to be replaced at most every 4 months. The saturation
of the activated charcoal depends on the more or less prolonged use
of the hood, on the type of cooking and on the regularity of cleaning the
grease filter. The filter has to be applied to the aspirating group, which
is inside the hood hiting the centre of the group with it and turning it of
90° degrees until the stop click is heard to lock it fig. 4.
USE AND MAINTENANCE
It is recommended to operate the appliance prior to cooking.
It is recommended to leave the appliance in operation for 15 minutes
after cooking is terminated in order to completely eliminate cooking
vapours and odours.
The proper function of the cooker hood is conditioned by the regularity
of the maintenance operations, in particular, the active carbon filter.
The anti-grease filters capture the grease particles suspended in the
air, and are therefore subject to clogging according to the frequency of
the use of the appliance.
In order to prevent fire hazard, it is recommendable to clean the filter
at a maximum of 2 months by carrying out the following instructions:
- Remove the filters from the cooker hood and wash them in a solution
of water and neutral liquid detergent, leaving to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several washes. This
is not cause for customer complaint nor replacement of panels.
The active carbon filters purify the air that is replaced in the environ-
ment. The filters are not washable nor re-useable and must be re-
placed at maximum every four months. The saturation of the active
carbon filter depends on the frequency of use of the appliance, by the
type of cooking and the regularity of cleaning the anti-grease filters.
Clean the fan and other surfaces of the cooker hood regularly using
a cloth moistened with denatured alcohol or non abrasive liquid deter-
gent.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE
WARNINGS.
ENGLISH
Download brugsanvisningen på Dansk (PDF, 0.56 MB)
(Tag hensyn til miljøet, og udskriv kun denne brugsanvisning, hvis det er virkelig nødvendigt)

Loading…

Bedømmelse

Fortæl os, hvad du synes om ETNA 4265NZT Emhætte ved at lave en produktbedømmelse. Vil du dele dine oplevelser med dette produkt eller stille et spørgsmål? Skriv en kommentar nederst på siden.
Er du tilfreds med ETNA 4265NZT Emhætte?
Ja Ingen
Vær den første til at bedømme dette produkt
0 stemmer

Deltag i samtalen om dette produkt

Her kan du dele, hvad du synes om ETNA 4265NZT Emhætte. Hvis du har et spørgsmål, skal du først læse brugsanvisningen omhyggeligt. Anmodning om en brugsanvisning kan ske ved at bruge vores kontaktformular.

Mere om denne brugsanvisning

Vi forstår, at det er rart at have en papirbrugsanvisning til din ETNA 4265NZT Emhætte. Du kan altid downloade brugsanvisningen fra vores hjemmeside og selv printe den. Hvis du gerne vil have en original brugsanvisning, anbefaler vi, at du kontakter ETNA. De kan muligvis levere en original brugsanvisning. Leder du efter brugsanvisningen til din ETNA 4265NZT Emhætte på et andet sprog? Vælg dit foretrukne sprog på vores hjemmeside, og søg efter modelnummeret for at se, om vi har det tilgængeligt.

Specifikationer

Mærke ETNA
Model 4265NZT
Kategori Emhætter
Filtype PDF
Filstørrelse 0.56 MB

Alle brugsanvisninger til ETNA Emhætter
Flere brugsanvisninger til Emhætter

Ofte stillede spørgsmål om ETNA 4265NZT Emhætte

Vores support-team søger efter nyttige produktoplysninger og svar på ofte stillede spørgsmål. Hvis du finder urigtigheder i vores ofte stillede spørgsmål, må du meget gerne lade os det vide ved at bruge vores kontaktformular.

Hvad skal afstanden være mellem mit kogesektion og min emhætte? Verificeret

Dette kan være lidt afhængingt af, hvilket mærke, der er tale om. Men generelt skal en emhætte placeres mindst 65 centimeter over et gaskkogesektion og mindst 50 centimenter over et elektrisk eller induktionskogesektion. Dette gøres for at øge brandsikkerheden.

Dette var nyttigt (1215) Læs mere

Har jeg brug for en emhætte med eller uden motor? Verificeret

Emhætter med motor er beregnet til når luften bevæges direkte udenfor. En emhætte uden motor er beregnet til når der er et centralt ventilationssystem. Tilslut aldrig en emhætte med motoren til et centralt ventilationssystem!

Dette var nyttigt (635) Læs mere
Brugsanvisning ETNA 4265NZT Emhætte

Relaterede produkter

Relaterede kategorier